EFFICIENCY CHECK OF SEWAGEPLANT AIA THROUGH A CONCEPTUAL MODEL OF SIMULATION

Main Article Content

Ivano Spiniello

Abstract

The paper describes a method aimed at checking the efficiency of a purifying plant in Aia for the treatment of liquid waste, processed through a conceptual model simulation. The modeling of the treatment cycle is based on the material balance of typical process engineering, is a predetermined volume of control are considered the terms of the mass of substance in input and in output, compared to the time interval and the reaction kinetics . Said method has been applied in the authorization phase Aia to the industrial wastewater treatment plant mixed type located in the province of Avellino in the industrial area of Lacedonia in order to verify the purifying efficiency of the treatment cycle designed to increase the quantity of landfill leachate treatable.

Article Details

Section
Articoli di ricerca
Author Biography

Ivano Spiniello, CGS scarl (società' unipersonale del consorzio ASI di Avellino)

Direttore tecnico degli impianti di depurazione reflui industriali ASI e rifiuti liquidi AIA